HP Integrity Virtual Server Manager 6.0 User Guide
Table 3 Network device icons (continued)
DescriptionIcon
Directory (folder)
Storage adapter
A question mark within the device icon, such as , indicates that the type of device cannot
be determined. The device type cannot be determined, for example, when the device has been
removed from the VSP but not from the virtual partition.
Virtual device type:
• The virtual device type and subset of the hardware path are shown with each virtual device.
This also indicates how the device is being used in the virtual partition.
Backing device:
The storage that backs a virtual device does not necessarily need to be the same type as the virtual
device itself; for example, a file can be the backing storage for virtual disks or virtual DVDs. A file
can be selected as a backing device for one of two purposes:
• The file is intended to represent the capacity of a virtual storage device. This storage space
is treated like a disk drive and can be used the way a disk drive is used (for example, by a
storage manager, or a raw device).
• The file is intended to represent a DVD or CD. In these cases, the file is an .ISO image of the
actual media.
A directory can be a backing device for a virtual DVD. A directory backing device is equivalent
to a physical DVD drive that is empty (the DVD was ejected or has not been inserted). The list of
files in the backing directory are ISO files, each representing a physical DVD that can be inserted
and used as the backing device.
If you eject a file-backed virtual DVD, the storage device is then backed by the directory in which
the ISO file was located. If you insert (select) an ISO file for a directory-backed DVD, the DVD
becomes a file-backed virtual DVD. For information about loading and ejecting a virtual DVD by
command from the virtual partition virtual console, see the HP Integrity Virtual Machines Installation,
Configuration, and Administration manual.
NOTE: If you use Virtual Server Manager to manage a VSP running Integrity VM Version 3.5 or
earlier, Virtual Server Manager does not fully support virtual device special files located in /hpap
(introduced in HP StorageWorks Secure Path software Version 3.0F SP2) as backing devices for
virtual storage. If a virtual storage device using an /hpap device special file already exists on a
virtual partition managed by Virtual Server Manager, Virtual Server Manager displays it on the
VSP Storage and vPar Properties Storage tabs as an unknown device (using the question mark
icon, ). Virtual Server Manager displays the correct device special file name (for example,
/hpap/rdsk/hpap1) but the box representing this device is not connected to the boxes that
represent the physical storage devices associated with that virtual device special file. In general,
Virtual Server Manager correctly displays only those device special files located in /dev.
Screen details
Storage tab column layout
Figure 19 depicts the column layout for the VSP Storage tab.
VSP view 37