HP Matrix Operating Environment 7.1 Release Notes

Shell> drvcfg
Configurable Components
Drv[2C] Ctrl[29] Lang[eng]
2. Enumerate all SCSI amd FC LUNs using drvcfg -s <drvnum> <ctrlnum>. drvnum and ctrlnum
are displayed as part of step 1. Press Y for confirmation on enumerating both SCSI and FC
LUNs.
Shell> drvcfg -s 2C 29
Set Configuration Options
Drv[2C] Ctrl[29] Lang[eng]
HP AVIO Stor Driver Configuration
==================================
Warning: Enumerating all SCSI or FC LUNs increases initialization times.
Enumerate all SCSI LUNs (Y/N)? [current setting: Y]: Y
Enumerate all FC LUNs (Y/N)? [current setting: Y]: Y
Drv[2C] Ctrl[29] Lang[eng] - Options set. Action Required is None
3. Reconnect drivers, refresh mapped drives and display available boot options using commands
"reconnect -r" and "map -r"
Shell> map -r
Device mapping table
blk0 : Acpi(PNP0A03,0)/Pci(1|0)/Fibre(WWN50001FE1501A1F39,Lun4068000000000000)
blk1 : Acpi(PNP0A03,0)/Pci(1|0)/Fibre(WWN50001FE1501A1F3D,Lun4068000000000000)
Moving a managed virtual machine guest using Microsoft SCVMM may change BIOS
serial number of logical server
On rare occasions, the BIOS serial number of a VM guest managed by logical server management
is changed if a file copy move operation is performed on the VM guest using Microsoft System
Center Virtual Machine Manager (SCVMM). This may cause operations on the virtual machine
logical server to be unsuccessful, or the virtual machine logical server may become inoperable.
Suggested action
Unmanage the logical server using the Matrix OE visualization DeleteUnmanage Logical Server...
menu selection, then import the virtual machine as a logical server using ToolsLogical
ServersImport....
Viewing or editing the logical server management properties file may cause failure of the
HP Logical Server Automation service
Viewing or editing the C:\Program Files\HP\Virtual Server Environment\conf\
lsa\lsa.properties file may write lock the file while the HP Logical Server Automation service
is running. This may cause a serious failure of the service.
Suggested action
Use a text editor that does not lock the file, such as Emacs, Notepad, or TextPad.
Process Resource Manager
Limitations
Creating and modifying configuration files with privilege elevation enabled is not supported
If privilege elevation is enabled in Systems Insight Manager, you can monitor Process Resource
Manager (PRM), but you may experience problems performing PRM operations. Specifically,
creating and modifying PRM configuration files may report success even though the operations
hang.
Suggested action
Do not change PRM configuration files using the PRM user interface when privilege elevation is
enabled.