Table 51 Requirements and capabilities for HP ProLiant BL servers (continued)
Intelligent
Power
Discovery
Data
Center
Power
Control
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO or OA
firmware
version
Server
model
✓✓✓✓✓✓NoneiLO 3
version
ProLiant
BL685c G7
1.05 and(AMD
OA version
3.10
Opteron
6100)
✓✓✓✓✓✓NoneiLO 3
version
ProLiant
BL685c G7
1.05 and(AMD
OA version
3.10
Opteron
6200)
1
For Enclosure Dynamic Power Capping, iLO 2 version 1.70 or newer. Otherwise, iLO 2 version 2 1.30 or newer.
For Enclosure Dynamic Power Capping, OA 2.30 or newer. Otherwise, OA 1.30 or newer.
2
When implementing power capping for HP BladeSystem, HP recommends using Enclosure Dynamic Power Capping set
through either the Onboard Administrator or Insight Control power management user interfaces. To use Enclosure Dynamic
Power Capping, you must upgrade your iLO 2 firmware to version 1.70 or greater and iLO 3 to version 1.0 or greater,
and are encouraged to update your system ROM to version 10/1/2008 or greater for iLO 2, and May 2010 or newer
for iLO 3 for G7 servers. For some older BL460c servers, the iLO 2 firmware may not be able to automatically update
the Dynamic Power Capping hardware circuit. In these instances, the Onboard Administrator will compensate for the
absence of the internal hardware circuit and continue to guarantee circuit protection.
3
This server model does not support HP Dynamic Power Savings mode.
Table 52 Requirements and capabilities for HP ProLiant workstation blades
Intelligent
Power
Discovery
Data
Center
Power
Control
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO or OA
firmware
version
Server
model
✓✓✓✓✓
1
✓8/5/2008iLO 2
version
1.60 or
later.
OA 2.30
or later.
ProLiant
xw2x220c
✓✓✓✓✓
2
✓7/31/2007iLO 2
version
1.30 or
later
ProLiant
xw460c
✓✓✓✓✓✓7/31/2007iLO 2
version
1.30 or
later
ProLiant
WS460c
G6
1
This server only supports Power Capping. It does not support Dynamic Power Capping.
2
When implementing power capping for HP BladeSystems, HP recommends using Enclosure Dynamic Power Capping
set through either the Onboard Administrator or Insight Control power management user interfaces. To use Enclosure
Dynamic Power Capping, you must upgrade your iLO 2 firmware to version 1.70 or greater and iLO 3 to version 1.0
or greater, and are encouraged to update your system ROM to version 10/1/2008 or greater for iLO 2, and May
2010 or later for iLO 3 for G7 servers. For some older BL460c servers, the iLO 2 firmware might not be able to
automatically update the Dynamic Power Capping hardware circuit. In these instances, the Onboard Administrator will
compensate for the absence of the internal hardware circuit and continue to guarantee circuit protection.
58 Hardware requirements and supported capabilities for Insight Control power management