HP Insight Dynamics 6.3 Release Notes
3 Issues and suggested actions
The issues and limitations in this release are listed in this chapter, organized by HP Insight Dynamics
feature or functional area. If a feature or functional area has no limitations or issues, that category
will not appear. The following categories are used:
Limitations Limitations of the implemented feature or functional area
Major issues Issues that may significantly affect functionality and usability
Minor issues Issues that may be noticeable but do not have a significant impact on
functionality or usability
HP Insight Dynamics software
Limitations
Configuring Insight Dynamics with a remote Microsoft SQL Server database
Because Windows Single Sign On is used by Insight Dynamics to connect to the SQL Server
database, the credentials associated with the user account executing a command or service are
used to connect to the remote database. Therefore, user accounts used to execute Insight Dynamics
software that accesses the database must satisfy the following conditions:
• The user credentials specified for the CMS access and database access during the installation
should be the same, and be trusted domain credentials available to both the CMS and database
systems.
• The user credentials specified during the installation for the database access should have
“Create Database“ access permissions to the database. The user must have “write” access to
the log files and “read/write” access after the installation.
If you run a CLI command as a user that is not a domain user or does not have database access
permission on the remote database, and the CLI command requires database access, the command
will fail.
Capacity Advisor
Limitations
Automatic power calibration of Integrity Linux systems running SUSE 11 operating system is not
supported
The HP Insight Dynamics software does not support the automatic power calibration of Integrity
Linux systems running the SUSE 11 operating system.
Suggested action
Manually calibrate Integrity Linux SUSE 11 systems for power.
Automatic power calibration requires power metering support in server
Auto-calibration of idle/max power with Capacity Advisor requires the power metering features
of iLO in the managed server. For information about which servers support power metering, see
Appendix A in the HP Insight Software Support Matrix at www.hp.com/go/insightdynamics/docs.
Suggested action
Manual power calibration is recommended for servers that do not support iLO power metering.
HP Insight Dynamics software 15