HP AppSystems for Virtualized SAP HANA

Technical white paper | HP AppSystem for Virtual SAP HANA
Virtual switch
The vmnic settings may change according to the networking options ordered with the appliance.
Data storage layout
There are three storage groups:
datastore1, local data store, system software and VM templates
datastorelarge, HANA database virtual disk and virtual machine images configuration files
fusion-io, HANA log virtual disks
Storage use is as follows:
P410i (boot controller) for the ESXi hypervisor (logical drive 299GB) and a local default datastore (datastore1).
P812 (25 drives RAID 50, logical drive of 5.99 TB) as a datastore for the virtual machines system disk and virtual
machines /HANA/data disk, and some space for virtual machine configuration files (datastorelarge).
Two Fusion-io devices, fct0 and fct1, that show up in the VMware storage manager. 785GB (less when
formatted). These are used for the virtual machines HANA log disks.
From the management server, view the storage adapters.
The following figure shows what the storage looks like from the vSphere Storage tab: two adapters for Fusion-io,
fioiom0 and fioiom1.