HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX

8
Repair Storage Module Procedure Generates “Will Cause Restripe
Warning Message (7433)
Scenario
When adding the repaired module to the cluster during the Repair Storage
Module procedure, a warning message is displayed that may give the
impression that the entire cluster will be restriped. This is not the case. Only
the repaired NSM will be restriped.
Workaround
Ignore the warning; just dismiss it.
Storage Module Takes Longer Than Normal To Come Up [NSM 150, NSM
160, NSM 260] (5994)
Scenario
You may sometimes notice a delay when adding storage module to a
management group immediately following RAID reconfiguration.
This behavior is rarely encountered because a storage module has RAID
configured at the factory.
Workaround
If you choose to reconfigure RAID from its factory settings to some other
configuration, wait five minutes before adding the storage module to a
management group.
Disks Are Not Hot-Swappable In The NSM 150, NSM 200, Or IBM
x3650 (3533)
These models do not support hot swap disk drives.