HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
7
Finding Storage Modules on Network
Windows Fire Wall Prevents Storage Module Discovery In The Centralized
Management Console (5855)
Scenario
After upgrading the SAN/iQ software, the Centralized Management Console
fails to discover storage modules.
Workaround
1 Determine if Windows Fire Wall is running.
2 If Windows Fire Wall is running, disable it.
Storage Modules
When Removing A Storage Module From A Group, Status Returns State As
Missing (7462)
Scenario
When swapping a storage module out of a cluster, it cannot be removed from
the management group after a restripe is completed. The storage module is
now in an unresponsive state and its status is: joining/leaving management
group, storage server state missing.
Workaround
Reboot the storage module. When it comes up, it is marked as available,
as expected.