HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
5
Workaround
Do either of these tasks:
• Let the upgrade finish before moving the storage module into a
management group.
• Move the storage module into a management group and then perform
the upgrade.
Upgrade Post-Qualification May Grab Focus Every 20 Seconds (2754)
Scenario
During a software upgrade, the Console may come to the front of other
windows open on the desktop and may grab focus as well.
Workaround
Click in a different window to re-establish focus elsewhere.
Upgrading Storage Modules And Management Groups May Take Some
Time (4234)
Scenario
Upgrading a storage module to the current release may take 30 to 40 minutes
depending upon the specific platform and configuration.
Even after the storage modules are upgraded, have rebooted, and have all
been found on the network in the Console, the upgrade process may take up to
another 10 minutes.
During the upgrade process, you may see messages such as “Waiting for MG1
to come up. The issue is - An NSM is down.” The storage module is not down.
It is actually resynchronizing with the other storage modules in the
management group.
Workaround
Wait for the resynchronization to complete.