HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
36
Workaround
To finish updating the IP address using the Console:
1 Log in to the storage module with the new IP address.
2 On the storage module, navigate to the TCP/IP Network category.
3 On the Communication tab, select Communications Tasks and click
Update Communications List.
This synchronizes the IP addresses of all managers.
MSCS
MSCS Cluster Failover While SAN/iQ Cluster Under Heavy Load Takes
MSCS Cluster Offline (1784)
If an MSCS cluster failover occurs while the SAN/iQ cluster is under very
heavy load, the MSCS cluster does not come back online until the load on the
SAN/iQ cluster decreases.
Workaround
Increase the pending timeout of each of the disk resources on the MSCS
cluster to match the maxrequestholdtime value, for example, 600.
Do the following on each physical disk resource that is actually an iSCSI disk
on the storage module.
1 Right-click on the disk in the MSCS cluster administrator.
2 Select Properties > Advanced tab.
3 Change the Pending Timeout: Seconds Field to match the
maxrequestholdtime value for iSCSI in the registry.