HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
32
# /etc/init.d/iscsi start
# vgchange -a y vgiSCSI
# mount /dev/vgiSCSI/lvol0 /iSCSI
After Power Cycle, Load Balancing Does Not Distribute Requests Properly
From A Microsoft Cluster (3993)
Scenario
A storage module is powered off and then powered on, and another storage
module in the SAN/iQ cluster handles all the connections to the volumes
connected to that cluster. When the storage module is powered on again, load
balancing does not redirect I/O to that storage module.
Workaround
1 Take one of the MS Cluster groups offline.
2 Disconnect the iSCSI connections on both storage modules.
3 Reconnect the targets on both storage modules.
4 Bring the MS Cluster group back online.
5 Repeat steps 1 through 4 for all MS Cluster groups that host SAN/iQ
iSCSI disks.
Load balancing will again distribute I/O requests across all storage modules.
2-way CHAP Does Not Work With Solaris 10 (4292)
Scenario
Volumes associated with an authentication group configured for 2-way CHAP
cannot be mounted on Solaris 10.
Workaround
Use 1-way CHAP or no CHAP with Solaris 10.