HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
28
Workaround
To designate enough bandwidth for I/O to the management group, reduce the
local bandwidth used for Remote Copy.
1 Log in to the remote management group.
2 On the Edit Remote Bandwidth dialog window, reduce the local
bandwidth setting.
iSCSI
Two-Way CHAP Can Be Done Using One-Way Chap Password (7370)
Scenario
For One-way CHAP, you have one password and use Outgoing Authentication.
For two-way CHAP, you have two different passwords, one for Incoming
Authentication and one for Outgoing Authentication.
Sometimes, you are able to mount a volume with two-way CHAP only using
one password.
Workaround
Use the single password for two-way CHAP until this issue is understood
more fully.
Adaptec HBA Unable To See Target (2348)
Workaround
Do not use MS iSCSI initiator with the Adaptec HBA.
iSCSI Closes All Shares After Reboot (3367)
If your iSCSI volumes are used by automatically-started Windows services, for
example, File Sharing, you must use the Microsoft Initiator's “Bind Volumes”
operation to make sure that those volumes are available before the services
that require them are started.