HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX

13
After Reboot, Lower Capacity Disk Status Is Shown As On And Secured In
An IBM x3650 That Has Higher Capacity Disks (6740)
Scenario
You insert a lower capacity disk in an IBM x3650 with higher capacity disks
and reboot it. In the Console, the physical drive status appears as Active, and
RAID status appears as Degraded. You will not be able to power off the lower
capacity disk to replace it with the higher capacity one.
Note
Adding lower capacity disks to storage modules with higher capacity disks is
not supported.
Workaround
1 Using the Console, power off the IBM x3650.
2 Replace lower capacity disk with a new, higher capacity disk.
3 Power on the IBM x3650.
When the IBM x3650 comes up, the RAID status appears as Rebuilding
and the physical drive status appears as Active.
In An NSM 200 With RAID 10, 3ware Controller May Not Bring New Disk
Online Without A Reboot (7629)
Scenario
If you replace a disk, there is a chance that the replacement disk will not be
recognized by the 3ware controller until you reboot the NSM 200.
Workaround
Reboot the NSM 200.