HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX
10
Boot Flash1 Status Changes After Changing RAID Configuration On NSM
150 ( 5498 )
Scenario
Changing the RAID configuration on an NSM 150 causes the Boot Flash1
status to change to Inactive for about 2 minutes. The status then changes to
Updating, and then back to Normal.
Explanation
This status change is due to the system processing the RAID reconfiguration.
If you use the factory default RAID configuration, you never see this alert. If
you configure the RAID to a different RAID setting, you see the status
changes one time.
RAID and Disk Management
Drive Shows As “Off or Removed” If The Storage Module Is Powered On
With A Missing Drive [NSM 160, NSM 260, DL 380, DL 320s] (7331, 7480)
Scenario
When a storage module is rebooted or powered on with a drive missing from
the drive bay, that drive will be reported as “Off or removed” by the Console. If
that drive is then inserted into the drive bay, it will not be recognized by
the Console.
Workaround
Reboot the storage module from the Console.
Disk Replacement [IBM x3650] (5968, 7543)
Replacing A Disk
1 Power off the original disk in the Console.
Warning: Incorrect disk replacement can corrupt the entire array.
To avoid such corruption, be sure to follow the procedures below: