HP LeftHand SAN Solutions Support Document - Service Notes - VSA 7.0 for VMware ESX

21
Battery Capacity Test Timing Changed [NSM 160] (7040)
Scenario
If you upgrade an NSM 160 from release 6.6.x to 7.0, the battery capacity test
runs every week instead of once every four weeks.
Workaround
After an upgrade, use the Console and manually change the BBU Capacity
Test monitoring variable frequency to four weeks. Select a NSM 160 storage
module > Alerts >Alert Setup> Edit Monitored Variable. Change the Schedule
Week field to Every Four Weeks.
“NVRAM Card = Corrupt” Alert May Be Generated When The Storage
Module Is Restarted After Being Shut Down For Some Time (4362)
Workaround
Call Support.
Management Groups
New User Unable To Change Original Password (7396)
Scenario
A new user logs in for the first time and wants to change his or her
administrator-assigned password. The new user tries the click path starting
at a management group > Administration> Edit User > Change Password and
Confirmation Password.
Click OK.
A message appears: Unable To Edit The User.
Workaround
Most likely, the new user belongs to a group that has only Read-Modify
permissions. A trustworthy administrator must assign a password to users
having this level of permissions. Read-Modify users cannot change their
own passwords.