HP SureStore HD Server 4000 User's Guide - 5967-9979
Shutting Down and Restarting 6
-
5
Shutting Down, Restarting, Cycling Power
The various types of restarting described in this section contain
references to operating states as described on page 6-10.
CAUTION!
❏
Switching the server’s power off without following the
appropriate shutdown procedure can result in lost user data.
Always make sure it is safe to cycle the power before doing so.
Alert users that the server will be off line (inaccessible) while
shut down; then complete the shutdown procedure before
switching off power.
Shutdown
Procedures
The shutdown procedures are used to disconnect client sessions and
to halt server operation, and are part of other procedures
recommended in this manual. The methods available to you, listed
below, depend on the state of the server.
Note
❏
Before doing any of the methods listed below, notify users that
the server will be off line and recommend they close all files.
•
From the initialization state, use the control panel’s setup
mode. Scroll to the
Shutdown Server
parameter. Press
✔
and
confirm with
✔
again.
•
From the normal operating state, you can use HD Server
Admin’s Configuration
Æ
Shutdown/Restart page. Click
Shutdown and Restart and
[Apply]
.
•
From the normal operating state, you can use the control
panel’s view mode. Press
✔
twice. Use
▲
or
▼
to scroll to the
Shutdown Server
parameter. Press
✔
and confirm with
✔
again.
When the server is shut down, it is halted with the control panel
displaying
Power off or ✔ to restart
until you take action. You
can either restart it by pressing
✔
, or you can switch the power off.