HP SureStore CD-ROM Server/Tower User's Guide - 5967-2149
9-4 Troubleshooting
Error Conditions
The following table shows how the front-panel indicators show
various problems. Look up the problem in the next section to
find the procedure to resolve it.
Status CD Network Disc ON/BUSY Problem to Look Up
Off — Off
On with CD
in
On with no
CD
Network connection faulty
Off Flash Blink *
Off with CD
in or\
Flash
On with
CD in
CD is defective/unreadable or
SCSI bus disconnected.
Check
config\stat.txt
file.
Off Off Blink * Off
Off with
CD in
CD has unsupported format
Off On — Off
Flash in
series of 5
CD read or drive problem.
Flash — —
On with CD
in
Off with
CD in
SCSI ID conflict with server
Flash Flash Blink *
On with CD
in
Off with
CD in
Illegal LAN hardware address
Flash Off Off
On with CD
in
Off with
CD in
Server failure: Flash load failed or
error in EEPROM
Flash Off Blink *
On with CD
in
Off with
CD in
Server failure: error in FLASH PROM
Flash Flash Off
On with CD
in
Off with
CD in
Run server diagnostic: error in SRAM or
DRAM/DIMM configuration error
Flash Off Off
On with CD
in
Off with
CD in
Run server diagnostic: error in
DRAM/DIMM
Flash Flash** Flash**
On with CD
in
Off with
CD in
Software/hardware combination error
* Blinks in synchrony with activity or access.
** The
CD
and
Network
indicators flash alternately in this condition.