Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

632 Fabric OS Message Reference
53-1002149-01
SPC-3011
98
SPC-3011
Message <timestamp>, [SPC-3011], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: Persistent data storage error: <SP
status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.
Probable Cause Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Run the initEE and regEE commands, then recover or restore the needed primary and secondary
KEKs.
Severity ERROR
SPC-3012
Message <timestamp>, [SPC-3012], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: Persistent data retrieval error: <SP
status code>.
Probable Cause Indicates an attempt to read Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Run initEE and regEE commands, then recover or restore the needed primary and secondary KEKs.
Severity ERROR
SPC-3013
Message <timestamp>, [SPC-3013], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: SEK generation failure: <SP status
code>.
Probable Cause Indicates the Crypto Module internal Secret Encryption Key could not be generated.
Recommended
Action
Contact your technical support.
Severity ERROR
SPC-3014
Message <timestamp>, [SPC-3014], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: RNG compare failure: successive
values match.
Probable Cause Indicates the Crypto Module internal random number generator has failed.