Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
212 Fabric OS Message Reference
53-1002149-01
FABR-1049
29
FABR-1049
Message <timestamp>, [FABR-1049], <sequence-number>,, ERROR, <system-name>, Detected
Fabric ID (FID <InheritedFID> inherited) conflict with neighbor switch
<Switchname> (domain <Domain ID>, FID <Fabric ID>). E-ports (<Number of E-ports
disabled>) connected to the switch are disabled.
Probable Cause Indicates that the neighbor switch has Fabric ID conflict with the inherited FID of the local switch.
All E_ports directly connected to the conflicting switch are disabled.
Recommended
Action
Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to
a VF-capable firmware.
Severity ERROR
FABR-1050
Message <timestamp>, [FABR-1050], <sequence-number>,, INFO, <system-name>, <License>
license not present. F-port trunking cannnot be enabled on port(<Port>).
Probable Cause Indicates that the Trunking or SAO license is not installed.
Recommended
Action
Install the required license.
Severity INFO
FABR-1051
Message <timestamp>, [FABR-1051], <sequence-number>,, ERROR, <system-name>, D-Port
<Testname> loopback test failed for slot <Slot> and port <Port>.
Probable Cause Indicates that the D-Port test failed for the given slot and port due to one of the following reasons:
• The SFP fault detected by Electrical loopback test failure.
• The cable fault detected by optical loopback test failure.
• An ASIC issue detected by remote loopback test failure.
Recommended
Action
Replace the faulty SFPs, cables, or blade.
Severity ERROR
FABR-1052
Message <timestamp>, [FABR-1052], <sequence-number>,, INFO, <system-name>, The configured
port speed (16G/10G on non C3 blade or 1G on C3 blade) is invalid. Persistently
disabling port <Port that is being disabled>.