Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

104 Fabric OS Message Reference
53-1002149-01
CDR-1012
14
Probable Cause Indicates that above normal errors were observed in hardware that may or may not impact the data
traffic.
Recommended
Action
Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists,
replace the blade.
Severity WARNING
CDR-1012
Message <timestamp>, [CDR-1012], <sequence-number>,, WARNING, <system-name>, S<slot
number>,P<port number>(<blade port number>): Port Fault: Hard <Hard fault>(<Fault
reason>) fault1=<Fault1 count> fault2=<Fault2 count> (0x<LIP and LLI fault count>
0x<RX_FIFO and HSS fault count> 0x<BWAIT fault count>).
Probable Cause Indicates that the port has failed. Port initialization will be retried.
Recommended
Action
Replace the SFP and the cable and then re-enable the port.
Severity WARNING
CDR-1014
Message <timestamp>, [CDR-1014], <sequence-number>,, WARNING, <system-name>, Link Reset
on Internal Port S<slot number>,P<port number>(<blade port number>) vc_no=<vc
number> crd(s)lost=<Credit(s) lost>.
Probable Cause Indicates that one or more credits were lost and the link is reset.
Recommended
Action
Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists,
replace the blade.
Severity WARNING
CDR-1015
Message <timestamp>, [CDR-1015], <sequence-number>,, WARNING, <system-name>, Port
re-initialized due to Link Reset failure on internal Port S<slot number>,P<port
number>(<blade port number>).
Probable Cause Indicates that port got re-initialized due to Link Reset failure.
Recommended
Action
Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists,
replace the blade.
Severity WARNING