HP IP/IPX Printer Gateway for NDPS - (English) Readme (version 3.00b)
28) GetJobPMLIndex Jobinfo attr tree getnext returned error status 2008 for
<printer_agent_name>
Explanation - 2008 is ERR_NORESP. This is due to the printer not
responding in time to an SNMP request. During the Job Monitor phase, the
HP Printer Gateway requests the PML index from the printer agent. However,
the printer does not respond in time, which may cause the printer agent goes
into “Not Bound”. This typically occurs on extremely busy networks or on
older devices.
What to do – Record all steps necessary to accurately reproduce this
problem. Then contact Technical Support.
29) Command line argument "" unknown for PA: <printer_agent_name>
Explanation – The HP Printer Gateway does not parse the command line
arguments (load string arguments) properly.
What to do – Record all steps necessary to accurately reproduce this
problem. Then contact Technical Support.
30) GetJobPMLIndex get next for JobAttr Info Tree returned error status 2008 for
<printer_agent_name>
Explanation - 2008 is ERR_NORESP. This is due to the printer not
responding in time to an SNMP request. During the Job Monitor phase, the
HP Printer Gateway requests the PML index from the printer agent. However,
the printer does not respond in time, which may cause the printer agent to go
into “Not Bound”. This typically occurs on extremely busy networks or on
older devices.
What to do - Record all necessary steps that are required to accurately
reproduce this problem then contact Technical Support.
31) Uknown return value from job monitor on <printer_agent_name> with job state
32192.
Explanation - This problem results from unexpected circumstances occurring
within the HP Gateway.
What to do - Record all steps necessary to accurately reproduce this
problem. Then contact Technical Support.
32) HPGATE: - 0 Severity:3
Explanation - 0 is a code error number’; 3 is the SEVERITY_CRITICAL
value.
What to do - Pay attention to the error message after this line.
33) GetJobPMLIndex Jobinfo attr tree getnext returned error status 1005 for
<printer_agent_name>
Explanation - 1005 is ERR_OTHER. The printer responds with a value
“other error” to the HP Printer Gateway’s SNMP request. During the Job
Monitor phase, the HP Printer Gateway requests for the PML index from the
printer. However, the printer does not respond with an expected result, which
may cause the printer agent to go into “Not Bound”.
What to do - Record all steps necessary to accurately reproduce this
problem. Then contact Technical Support.