HP IP Distance Gateway (mpx 110) Release Notes (5697-1889, April 2012)
• HP P9000 Continuous Access XP
• HP P9000 XP Array Manager
• HP P10000 3PAR V-Class, F-Class, T-Class
• HP P10000 3PAR Remote Copy
Operating systems and multipath support
The mpx110 supports all P6000 and P9000 Continuous Access and P10000/3PAR Remote Copy
supported operating systems and multipath software. For additional information, see the HP
Continuous Access documentation on the HP website: nlhttp://www.hp.
nl
http://www.hp.com/storage
You can also access the HP Enterprise Virtual Array compatibility reference on the HP website:
nl
http://h18006.www1.hp.com/products/storage/software/conaccesseva/index.html
Fixes and enhancements
The following fix and enhancement are included in firmware version 2.4.4.6:
• Failure of ISL formation due to increased FC frame payload. Increased the allowable FC frame
payload to accommodate additional headers.
• TCP Timer Expired counter display modified
Prerequisites
The following prerequisites must be met to install firmware version 2.4.4.6:
• HP mpx Manager version 2.0.30, build 127 (minimum)
• Local and remote P6000/EVA, P9000/XP, or P10000/3PAR storage systems
• Local and remote B-series, C-series, or H-series Fibre Channel fabrics
• Dedicated IP network for FCIP connectivity
Installation instructions
For information about installing these products, see the HP IP Distance Gateway quick start
instructions and the HP IP Distance Gateway user guide, available on the HP website:
nl
http://h18006.www1.hp.com/products/storageworks/fcipd_gateway/index.html
At the website, under Support, select Support for your product, and then under Resources for HP
IP Distance Gateway, select Manuals.
Important information
This section contains important information about the current release.
CLI and mpx manager GUI display time difference
When the mpx110 time is changed using the date command in the CLI, the CLI will display the
correct local time of the mpx110. However, the mpx manager GUI will offset the mpx110 time
with its local host time zone, resulting in display of a different time.
E_Port unknown with B-series Fibre Channel switches using firmware version 5.2.0x
When connecting two B-series fabrics through FCIP using IP Distance Gateways, Fibre Channel
switches with firmware 5.2.0x may not connect successfully, in which case they will report E_Port
unknown.
4