HP-UX Virtual Partitions Administrator Guide (includes A.05.09) (5900-2188, March 2012)

vPars Database Changes
As part of the upgrade process, HP qualified service personnel will need to make updates to each
virtual partition’s vPars database (vpdb) in nPars mode following the server hardware changes.
These and other necessary steps are described in the HP I/O Hardware Upgrade Scripts Guide
for HP Integrity Superdome/sx2000 Servers and HP-UX Impacts on the Upgrade Process for the
rx8620 to rx8640 Hardware Upgrade service documents.
Hardware Path Tables
The tables below show the new hardware paths. For details on the new hardware paths and other
hardware information, see the applicable hardware upgrade manuals for your server.
Table 19 rx7620 to rx7640 Hardware Path Changes
Descriptionrx7640 Pathrx7620 Path
Top right HDD using A6794A or AB290A1/0/1/1/0/4/1.61/0/1/1/0/1/1.6
Bottom left HDD using MP/SCSI0/0/0/3/0.60/0/0/3/0.6
Bottom right HDD using MP/SCSI or AB290A0/0/1/1/0/4/1.50/0/0/3/0.5
Internal DVD/tape (x=2 for DVD, x=3 for DAT)1/0/0/3/1.x1/0/0/3/1.x
Bottom slimline DVD, if present0/0/0/3/1.2
Primary LAN1/0/1/1/0/6/01/0/1/1/0/4/0
Secondary LAN1/0/1/1/0/6/1
Primary LAN0/0/1/1/0/6/00/0/8/1/0/4/0
Secondary LAN0/0/1/1/0/6/1
external SCSI (A6794A/AB290A)1/0/1/1/0/4/0.x1/0/1/1/0/1/0.x
external SCSI (AB290A), shared with internal HDD1/0/1/1/0/4/1.x
external SCSI (A6794A/AB290A)0/0/1/1/0/4/0.x0/0/8/1/0/1/0.x
external SCSI (AB290A), shared with internal HDD0/0/1/1/0/4/1.x
Table 20 rx8620 to rx8640 Hardware Path Changes
Descriptionrx8640 Pathrx8620 Path
simplecomN/A0/0/0/0/0
console UART[rootcell]/250/20/0/0/0/1
simplecomN/A1/0/0/0/0
console UART[rootcell]/250/21/0/0/0/1
Table 21 Integrity Superdome Hardware Path Changes (
x=cell
)
sx2000 Pathsx1000 PathSlot
x/0/0/1x/0/0/10
x/0/1/1x/0/1/11
x/0/2/1x/0/2/12
x/0/4/1x/0/3/13
x/0/5/1x/0/4/14
x/0/6/1x/0/6/15
Upgrading Integrity Servers from the sx1000 to sx2000 Chipset 109