HP Array Configuration Utility Command Line Interface for Integiry Linux Environments Support Notes Version 8.70
• OS fails to recognize configuration changes.
THIS ISSUE WAS FIXED IN THE 7.65 RELEASE.
When existing volumes are modified or deleted, or when new volumes are created using
HP ACU-CLI, the operating system will not always be aware of the changes unless the
system is rebooted.
Workaround: You must reboot the system after making changes to existing volumes.
• ACU-CLI cannot delete the last logical disk.
THIS ISSUE WAS FIXED IN hpacucli8.40+hp-fc-enablement-1.1-13.
ACU-CLI cannot delete the last logical disk that connects to the Qlogic Fibre Channel card.
This issue only happens on RHEL5.3, SLES11, RHEL5.4 and SLES10SP3.
Workaround: The last disk can be deleted on RHEL4 and SLES10SP2
• Mount point displays as "None" after mounting the LD into the OS.
THIS ISSUE WAS FIXED IN hpacucli8.40+hp-fc-enablement-1.1-13.
After mounting your logical drive into the operating system and executing the command
"ld <your id number> show", the system displays the message [None] as the status for
the mount points.
Workaround: Execute the command mount from the command line to display the correct
mount points for your LD.
• hpacucli acts abnormal with the qlogic card and the hp-fc-enablement rpm.
THIS ISSUE WAS FIXED IN hpacucli8.40+hp-fc-enablement-1.1-13.
hpacucli fails to delete the last array due to an issue with the qlogic driver and
hp-fc-enablement lib. This issue occurs on RHEL5.3, RHEL5.4, SLES10SP3, and SLES11.
Workaround: This issue fix requires both the qlogic driver and the hp-fc-enablement
lib fix. The target operating systems for the qlogic driver fix are RHEL5.5 and SLES10SP3.
The lib fix issue will be fixed with version 1.1-9. For the RHEL5.4 and SLES10SP3 operating
systems the fix version will be 1.2-1+.
• hpacuscripting return code is not "0".
On HP Integrity servers running RHEL5.4, RHEL4.8, SLES10SP3, or SLES11SP1, run the
command "$hpacuscripting -i acuinput.ini -internal" on SmartArray
controllers. The return code is not 0, but 12. The error.ini file that is created will have
the content ERROR: (2828) New Array ID already exists, requested Array
ID: A Controller HP Smart Array 6400, SLOT7.
Run the command$hpacuscripting -i acuinput.ini -external" on FibreChannel
controllers. the return code is not "0", but "48". An "error.ini" file that is created with
have the content ERROR: (2864) Invalid Preferred Path Mode, line 20:
"PREFERREDPATHMODE= AUTOMATIC".
Workaround: This error does not affect functionality. If you set PREFERREDPATHMODE=
MANUAL in acucli, the issue will be resolved.
Support
Support for HP ACU-CLI or Smart Array controllers can be obtained at the HP Customer Care
web site at:
http://support.hp.com
Feedback
For feedback or suggestions regarding HP ACU-CLI, e-mail your comments to:
acu@hp.com
8