HP Integrated Lights-Out Addendum

0—No change
1—Disabled
2—Enabled (no authentication required)
3—Enabled (authentication required)
The SERIAL_CLI_SPEED parameter specifies the CLI port speed. The
possible values are as follows:
0—No change
1—9,600 bps
2—19,200 bps
3—38,400 bps
4—57,600 bps
5—115,200 bps
The ENFORCE_AES parameter determines if iLO enforces the use of
AES/3DES encryption ciphers over the iLO interface, SSH, and XML
connections. The possible values are Yes and No.
The VSP_SOFTWARE_FLOW_CONTROL parameter determines if
iLO enforces the use of software flow control for Virtual Serial Port.
The possible values are Yes and No.
MOD_GLOBAL_SETTINGS runtime errors
The possible MOD_GLOBAL_SETTINGS error messages include:
RIB information is open for read-only access. Write access is
required for this operation.
User does not have correct privilege for action.
CONFIG_ILO_PRIV required.
Unrecognized keyboard model.
Global Settings parameters
Settings (parameters) found on the Access Options page of the iLO
user interface.
Parameter Default value Descriptions
Idle
Connection
Timeout
(minutes)
30 minutes This setting specifies the
interval of user inactivity, in
minutes, before the web
server and Remote Console
session automatically
terminate. The following
settings are valid: 15, 30,
60, 120 minutes, or 0
(infinite). The infinite timeout
value does not log out
inactive users.
Parameter Default value Descriptions
Lights-Out
Functionality
Enabled This setting enables
connection to iLO. If
disabled, all connections to
iLO are prevented.
The iLO 10/100 network
and communications with
operating system drivers are
turned off if Lights-Out
functionality is disabled. The
iLO Diagnostic Port for an HP
ProLiant BL p Class server is
also disabled.
If iLO functionality is disabled
(including the iLO Diagnostic
Port), you must use the
server's Security Override
Switch to enable iLO. See
your server documentation to
locate the Security Override
Switch and set it to override.
Power up the server and use
the iLO RBSU to set Lights-
Out Functionality to Enabled.
Require Login
for iLO RBSU
Disabled This setting enables RBSU
access with or without a user-
credentials challenge. If this
setting is Enabled, and you
press F8 during POST to
enter iLO RBSU. A login
dialogue appears.
Show iLO
during POST
Disabled This setting enables the
display of the iLO network IP
address during the host
server POST process.
Serial
Command
Line Interface
Status
Enabled-
Authentication
Required
This setting enables you to
change the login model of
the CLI feature through the
serial port. The following
settings are valid:
Enabled—Authentication
Required
Enabled—No
Authentication
Disabled