HP iLO 4 User Guide

When a physical drive has a Failed status, this status does not affect the overall storage health
status. Only logical drives affect the storage health status.
The following information is listed for the physical drives attached to an HP Smart Array controller:
Physical drive port, box, and bay numbers
Physical drive status
Physical drive serial number
Physical drive model number
Physical drive capacity
Physical drive location
Physical drive firmware version
Physical drive configuration
Encryption status
Viewing firmware information
The Firmware Information page displays firmware information for various server components.
If the server is powered off, the system health information on this page is current as of the last
power off. Health information is updated only when the server is powered on and POST is complete.
To view firmware information, navigate to the InformationSystem Information page, and then
click the Firmware tab, as shown in Figure 83 (page 169).
Figure 83 System Information Firmware Information page
The following information is displayed:
Firmware Name—The name of the firmware.
The firmware types listed on this page vary based on the server model and configuration.
For most servers, the HP ProLiant System ROM and the iLO firmware are listed. Other possible
firmware options include the Power Management Controller, Server Platform Services, HP
Smart Array, Intelligent Provisioning, and networking adapters.
NOTE: To view firmware information for hard drives, navigate to the System
InformationStorage page.
Firmware Version—The version of the firmware.
Viewing iLO system information 169