HP iLO 3 Scripting and Command Line Guide
<POWER_SUPPLIES STATUS= "Failed"/>
<POWER_SUPPLIES REDUNDANCY= "Not Redundant"/>
<PROCESSOR STATUS= "OK"/>
<MEMORY STATUS= "OK"/>
<NETWORK STATUS= "Link Down"/>
<STORAGE STATUS= "OK"/>
</HEALTH_AT_A_GLANCE>
</GET_EMBEDDED_HEALTH_DATA>
Variable POWER_SUPPLIES tags:
• The POWER_SUPPLIES tags HP_POWER_DISCOVERY_SERVICES_REDUNDANCY_STATUS
and HIGH_EFFICIENCY_MODE appear only for blade servers.
• The following POWER_SUPPLIES tags appear only when SNMP is available, otherwise they
are replaced by the tags SUPPLY_LABEL AND SUPPLY_STATUS:
◦ PRESENT
◦ PDS
◦ HOTPLUG_CAPABLE
◦ MODEL
◦ SPARE
◦ SERIAL_NUMBER
◦ CAPACITY
◦ FIRMWARE_VERSION
• The following POWER_SUPPLIES tags appear only when an iPDU is present:
◦ POWER_DISCOVERY_SERVICES_IPDU_SUMMARY
◦ IPDU
◦ BAY
◦ STATUS
◦ PART_NUMBER
◦ SERIAL_NUMBER
◦ MAC_ADDRESS
◦ IPDU_LINK
GET_POWER_READINGS
The GET_POWER_READINGS command is used to get the power readings from the server power
supply.
For example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="read">
<GET_POWER_READINGS/>
</SERVER_INFO>
</LOGIN>
</RIBCL>
130 RIBCL XML Scripting Language