iLO 2 User Guide
7 Troubleshooting iLO 2
iLO 2 POST LED indicators
During the initial boot of iLO 2, the POST LED indicators flash to display the progress through the
iLO 2 boot process. After the boot process is complete, the HB LED flashes every second. LED 7
also flashes intermittently during normal operation.
The LED indicators (1 through 6) light up after the system has booted to indicate a hardware failure.
If a hardware failure is detected, reset iLO 2. For the location of the LED indicators, refer to the
server documentation.
A runtime failure of iLO 2 is indicated by HB and LED 7 remaining in either the On or Off state
constantly. A runtime failure of iLO 2 can also be indicated by a repeated flashing pattern on all
eight LEDs. If a runtime error occurs, reset iLO 2.
A sequential flashing pattern on LEDs, 1, 2, 3, 4, 5, 6, 7, and 8, repeating indefinitely, indicates
iLO 2 has experienced a failed flash (firmware upgrade) and is in the flash recovery mode. Refer
to the "iLO network flash recovery" section for more information.
The LED indicators have the following assignments:
1234567HB
Failure indicatedDescriptionPOST code (activity
completed)
LED indicator
Set up chip selects.00None
Determine platform.02 Normal operation1 or 2
Set RUNMAP bit.032 and 1
Initialize SDRAM controller.043
Activate the I cache.063 and 2
Initialize (only) the D cache.073, 2, and 1
Could not copy secondary
loader.
Copy secondary loader to
RAM.
084
Did not execute secondary
loader.
Verify secondary loader.094 and 1
SDRAM memory test failed.Begin secondary loader.0a4 and 2
Could not copy boot block.Copy ROM to RAM.0b4, 2, and 1
Boot block failed to execute.Verify ROM image in RAM.0c4 and 3
Boot block could not find a
valid image.
Boot Block Main started.0d4, 3, and 1
Start C Run time
initialization.
None
Main self-test failed.Main() has received control.0e4, 3, and 2
Each subsystem might
self-test.
VariesVaries
RTOS startup failed.Start ThreadX.0f4, 3, 2, and 1
182 Troubleshooting iLO 2