iLO 2 User Guide

The following fields are available:
Rack name
Rack serial number
Enclosure name
Enclosure serial number
Enclosure type
Firmware revision
Hardware revision
Load balance wire
Enclosure temperature
Enclosure temperature side A and B
Management Module UID
Certain fields can be changed and updated by clicking Apply.
Network component information
Network component information displays the status of the patch panel or interconnect switch that
has been selected. The information displayed includes Fuse A, Fuse B, and Network Component
Type.
iLO 2 control of ProLiant BL p-Class server LEDs
iLO 2 can monitor BL p-Class servers through POST tracking and the Server Health LED.
Server POST tracking
Feedback is limited while the server is booting because of the headless nature of the ProLiant BL
p-Class servers. iLO 2 provides boot-time feedback by flashing the Server Health LED green during
server POST. The LED is set to solid amber if the boot is unsuccessful. The LED is set to solid green
at the end of a successful boot.
After a successful boot, control of the Server Health LED is returned to the server, which can turn
the LED off or set it to some other color to represent the health of the server hardware.
ProLiant BL p-Class Advanced management 123