iLO 2 Scripting and Command Line Guide
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RIB_INFO_MODE="write">
<COMPUTER_LOCK_CONFIG>
<COMPUTER_LOCK value="custom"/>
<COMPUTER_LOCK key="l_gui,l"/>
</COMPUTER_LOCK_CONFIG>
</RIB_INFO_MODE="write">
</LOGIN>
</RIBCL>
Disabled example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RIB_INFO_MODE="write">
<COMPUTER_LOCK_CONFIG>
<COMPUTER_LOCK value="disabled"/>
</COMPUTER_LOCK_CONFIG>
</RIB_INFO_MODE="write">
</LOGIN>
</RIBCL>
COMPUTER_LOCK_CONFIG parameters
The computer lock on Windows-based operating systems defaults to the Windows logo + L keys.
You can customize Linux and other operating systems by setting the <COMPUTER_LOCK
value="custom"/> parameter. For example:
<COMPUTER_LOCK key="l_gui,l"/>
COMPUTER_LOCK_CONFIG runtime errors
The possible COMPUTER_LOCK_CONFIG error messages include:
• RIB information is open for read-only access. Write access is required for this operation.
• Invalid number of parameters. The maximum allowed is five.
• User does not have correct privilege for action. CONFIG_ILO_PRIV required.
• Invalid COMPUTER_LOCK option; value must be windows, custom, or disabled.
• COMPUTER_LOCK value must be set to custom to use the COMPUTER_LOCK_KEY tag.
• The COMPUTER_LOCK key command was used without a preceding COMPUTER_LOCK value
command equal to custom.
• The key parameter specified is not valid
GET_NETWORK_SETTINGS
The GET_NETWORK_SETTINGS command requests the respective iLO 2 network settings. For this
command to parse correctly, the command must appear within a RIB_INFO command block, and
RIB_INFO MODE can be set to read or write.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RIB_INFO MODE="read">
<GET_NETWORK_SETTINGS/>
90 Using RIBCL