DefinitionDefault valueParameter
This option sets the port number used to connect to the
directory server. The SSL-secured LDAP port number is 636.
636Directory server LDAP port
This option specifies the unique name for the iLO 2 in the
directory. LOM Object Distinguished Names are limited
to 256 characters.
LOM object distinguished name
This parameter specifies the password for the iLO 2 object
to access the directory. LOM Object Passwords are limited
to 39 characters.
LOM object password
NOTE: At this time, the LOM Object Password field is
not used. This field is to provide forward compatibility with
future firmware releases.
Prevents mistyped passwords. If you change the LOM
Object Password, also enter the new password in this field.
LOM object password confirm
This parameter enables you to specify up to 15 searchable
contexts used to locate the user when the user is trying to
Directory user context 1, directory
user context 2, ... up to directory
user context 15 authenticate using the directory. Directory User Contexts
are limited to 128 characters each. Directory User Contexts
enable you to specify directory user containers that are
automatically searched when an iLO 2 login is attempted.
This eliminates the requirement of entering a fully
distinguished user name at the login screen. For example,
the search context, "ou=lights out devices,o=corp" would
allow the user "cn=manager,ou=lights out devices,o=corp"
to login to iLO 2 using just "manager." Active Directory
allows an additional search context format, "@hostname"
for example, "@directory.corp."
BL p-Class parameters
DefinitionDefault valueParameter
The rack name is used to logically group together the components
that compose a single rack. When changed, the rack name is
Provided by rackRack name
communicated to all other components connected in a rack. The
name is used when logging and alerting to assist in identifying the
component.
The enclosure name is used to logically group together the server
blades that compose a single enclosure. When changed, the
Provided by rackEnclosure name
enclosure name is communicated to all other server blades
connected in the same enclosure. The name is used when logging
and alerting to assist in identifying the component.
The bay name is used when logging and alerting to assist in
identifying a component or its function.
Bay name
The ProLiant BL p-Class enclosure can support one to eight server
blades. The bays are numbered from left to right starting with 1
Provided by rackBay
and finishing with 8. The bay number is used to assist in physically
identifying the faulty server blade or other error conditions. This
information is for viewing only.
The rack serial number identifies the components in the rack as a
logical grouping. The serial number is determined during power-up
Provided by rackRack serial number
of the various components to create a unique rack serial number.
Switching components (server blade enclosure or power supplies)
alters the rack serial number.
The enclosure serial number identifies the particular server blade
enclosure in which a server blade resides.
Provided by rackEnclosure serial number