HP Integrated Lights-Out 2 User Guide

Table Of Contents
Install Software screen
This step of the installation wizard enables you to launch the Remote Console and install the
operating system. To start the operating system installation process:
Click Launch Software Installation to launch the Remote Console. iLO 2 automatically initiates
a server power-on or reboot to start the operating system installation through the previously
selected virtual media.
Accept security certificates as they appear.
Click Finish to complete the setup process.
iLO 2 diagnostic port configuration parameters
The iLO 2 Diagnostic Port on the front of ProLiant BL p-Class servers enables you to access and
troubleshoot server issues by using a diagnostic cable. The iLO 2 Diagnostic Port uses a static IP
address. It does not use DHCP to obtain an IP address, register with WINS or dynamic DNS, or
use a gateway. The diagnostic port cable must not be left plugged in without an active network
connection because it will cause degraded network performance on the standard iLO 2 network
port.
In Network Settings, you can configure specific diagnostic port information. For more information
on using the diagnostic port and the diagnostic cable, see to the setup and installation guide for
the blade server.
The following are the fields that can be configured for the Diagnostic Port:
Enable NIC
If Enable NIC is set to Yes, the diagnostic port is enabled.
Transceiver Speed Autoselect
Speed
Duplex
IP Address
Use this parameter to assign a static IP address to iLO 2 on your network. By default, the IP
address is assigned by DHCP. By default, the IP address is 192.168.1.1 for all iLO 2
Diagnostic Ports.
Subnet Mask
Use the subnet mask parameter to assign the subnet mask for the iLO 2 Diagnostic Port.
By default, the subnet mask is 255.255.255.0 for all iLO 2 Diagnostic Ports.
The use of the Diagnostic Port is automatically sensed when an active network cable is
plugged in to it. When switching between the diagnostic and back ports, you must allow
90 seconds for the network switchover to complete before attempting connection through
the web browser.
NOTE: The diagnostic port does not switch over if an active Remote Console session
or a firmware update is in progress.
ProLiant BL p-Class configuration 73