To configure alerts:
1. Log in to iLO 2 using an account that has the Configure iLO 2 Settings privilege.
2. Select Management in the Administration tab. The SNMP/Insight Manager Settings screen
appears.
3. In the SNMP Alert Destination(s) fields, enter up to three IP addresses that you want to receive
the SNMP alerts and select the alert options you want iLO 2 to support.
4. Click Apply Settings.
Test alerts include an Insight Manager SNMP trap and are used to verify the network connectivity
of iLO 2 in HP SIM. Only users with the Configure iLO 2 Settings privilege can send test alerts.
Be sure you have saved any changes to the SNMP Alert Destination(s) fields before sending a test
alert.
To send a test alert:
1. Select Management in the Administration tab. The SNMP/Insight Manager Settings screen
appears.
2. Click Send Test Alert in the Configure and Test SNMP Alerts section to generate a test alert
and send it to the TCP/IP addresses saved in the SNMP Alert Destinations fields.
3. After generating the alert, a confirmation screen appears.
4. Check the HP SIM console for receipt of the trap.
SNMP generated trap definitions
You can generate the following SNMP traps on BL c-Class servers and iLO 2:
ALERT_TEST – Verifies that the SNMP configuration, client SNMP console, and network are
operating correctly. You can use the iLO 2 interface to generate this alert to verify receipt of
the alert at the SNMP console. You can also generate this alert using the iLO 2 Option ROM
to verify SNMP configuration settings.
ALERT_SERVER_POWER – Occurs when the iLO 2 management processor detects an
unexpected transition of the host system power, either from ON to OFF, or OFF to ON.
Transitions of the host system power are unexpected when the change takes place because
of events unknown to the management processor. This alert is not generated when the system
is powered up or down using the iLO 2 interface, CLI, RIBCL or other management feature. If
the server is powered down because of the operating system, physical power button presses,
or other methods, the alert is generated and sent.
ALERT_SERVER_RESET – Occurs when the iLO 2 management processor is used to perform
a cold boot or warm boot of the host system. This alert is also sent when the iLO 2 management
66 Configuring iLO 2