HP Integrated Lights-Out 2 User Guide
Table Of Contents
- HP Integrated Lights-Out 2 User Guide
- Contents
- 1 Overview
- 2 Setting up iLO 2
- 3 Configuring iLO 2
- iLO 2 configuration overview
- Upgrading iLO 2 firmware
- Licensing
- User administration
- Configuring iLO 2 access
- Security
- Network
- SNMP/Insight Manager settings
- ProLiant BL p-Class configuration
- 4 Using iLO 2
- System status and status summary information
- iLO 2 Remote Console
- Remote Console overview and licensing options
- Remote Console settings
- IRC Fullscreen
- Integrated Remote Console option
- Multi-user access to the Integrated Remote Console
- Using Console Capture
- Using HP iLO Video Player
- Acquiring the Remote Console
- Remote Console
- Text-based remote console overview
- Virtual media
- Power management
- ProLiant BL p-Class Advanced management
- ProLiant BladeSystem HP Onboard Administrator
- 5 Directory services
- Overview of directory integration
- Benefits of directory integration
- Advantages and disadvantages of schema-free directories and HP schema directory
- Setting up Schema-free directory integration
- Setting up HP schema directory integration
- Features supported by HP schema directory integration
- Setting up directory services
- Schema documentation
- Directory services support
- Schema required software
- Schema installer
- Management snap-in installer
- Directory services for Active Directory
- Active Directory installation prerequisites
- Installing Active Directory on Windows Server 2008
- Directory services preparation for Active Directory
- Snap-in installation and initialization for Active Directory
- Example: Creating and configuring directory objects for use with iLO 2 in Active Directory
- Directory services objects
- Active Directory Lights-Out management
- Directory services for eDirectory
- User login using directory services
- Directory-enabled remote management
- HPQLOMIG directory migration utility
- Introduction to HPQLOMIG utility
- Compatibility
- HP Lights-Out directory package
- Using HPQLOMIG
- Finding management processors
- Upgrading firmware on management processors
- Selecting a directory access method
- Naming management processors
- Configuring directories when HP Extended schema is selected
- Configuring directories when schema-free integration is selected
- Setting up management processors for directories
- Directory services schema
- 6 HP Systems Insight Manager integration
- 7 Troubleshooting iLO 2
- iLO 2 POST LED indicators
- Event log entries
- Hardware and software link-related issues
- JVM support
- Login issues
- Login name and password not accepted
- Directory user premature logout
- iLO 2 Management Port not accessible by name
- iLO 2 RBSU unavailable after iLO 2 and server reset
- Inability to access the login page
- Inability to access iLO 2 using Telnet
- Inability to access virtual media or graphical remote console
- Inability to connect to iLO 2 after changing network settings
- Inability to connect to the iLO 2 Diagnostic Port
- Inability to connect to the iLO 2 processor through the NIC
- Inability to log in to iLO 2 after installing the iLO 2 certificate
- Firewall issues
- Proxy server issues
- Two-factor authentication error
- Troubleshooting alert and trap issues
- Troubleshooting directory issues
- Troubleshooting Remote Console issues
- Remote Console applet has a red X when running Linux client browser
- Inability to navigate the single cursor of the Remote Console to corners of the Remote Console window
- Remote Console no longer opens on the existing browser session
- Remote console text window not updating properly
- Remote Console turns gray or black
- Remote Serial Console troubleshooting
- Troubleshooting Integrated Remote Console issues
- Internet Explorer 7 and a flickering remote console screen
- Configuring Apache to accept exported capture buffers
- No console replay while server is powered down
- Skipping information during boot and fault buffer playback
- Out of Memory error starting Integrated Remote Console
- Session leader does not receive connection request when IRC is in replay mode
- Keyboard LED does not display correctly
- Inactive IRC
- IRC Failed to connect to server error message
- IRC toolbar icons do not update
- GNOME interface does not lock
- Repeating keys on the Remote Console
- Remote Console playback does not work when the host server is powered off
- Troubleshooting SSH and Telnet issues
- Troubleshooting terminal services issues
- Troubleshooting video and monitor issues
- Troubleshooting Virtual Media issues
- Troubleshooting iLO Video Player issues
- Troubleshooting Remote Text Console issues
- Troubleshooting miscellaneous issues
- Cookie sharing between browser instances and iLO 2
- Inability to access ActiveX downloads
- Inability to get SNMP information from HP SIM
- Incorrect time or date of the entries in the event log
- Inability to upgrade iLO 2 firmware
- iLO 2 network flash recovery
- Recovering from a bad iLO 2 flash image using network flash recovery
- Recovering from a bad iLO 2 flash image using the HP Smart Update Firmware DVD
- The iLO 2 firmware does not respond to SSL requests
- Testing SSL
- Resetting iLO 2
- Server name still present after ERASE utility is executed
- Troubleshooting a remote host
- 8 Technical support
- Acronyms and abbreviations
- Index

obscured and unavailable during this time. You cannot use a physical local floppy drive and
the Virtual Floppy simultaneously.
• Windows Server 2008 or later and Windows Server 2003
Virtual Floppy and USB key drives appear automatically after Microsoft Windows has
recognized the mounting of the USB device. Use it as you would a locally attached device.
To use Virtual Floppy during a Windows installation as a driver diskette, disable the integrated
diskette drive in the host RBSU which forces the Virtual Floppy to appear as drive A.
To use Virtual USBKey during a Windows installation as a driver diskette, change the boot
order of the USB key drive in the system RBSU. HP recommends placing the USB key drive
first in the boot order.
• Windows Vista
Virtual media does not work correctly on Windows Vista using Internet Explorer 7 with Protected
Mode enabled. If you attempt to use virtual media with Protected Mode enabled, various error
messages appear, including could not open cdrom (the parameter is incorrect.
To use virtual media, click Tools/Internet Options/Security, clear Enable Protected Mode, then
click Apply. After disabling Protected Mode, you must close all open browser instances and
restart the browser.
• NetWare 6.5
NetWare 6.5 supports the use of USB diskette and key drives. For step-by-step instructions,
see “Mounting USB Virtual Floppy/USBKey in NetWare 6.5” (page 107).
• Red Hat and SUSE Linux
Linux supports the use of USB diskette and key drives. For step-by-step instructions, see
“Mounting USB Virtual Media/USBKey in Linux” (page 108).
Operating system USB support
To use virtual media devices your operating system must have support for USB devices. Your
operating system must also support USB mass storage devices. Currently, Windows Server 2008,
Windows 2003, Red Hat Enterprise Linux 3, Red Hat Enterprise Linux 4, Red Hat Enterprise Linux
5, SUSE SLES 9, and SUSE SLES 10 support USB devices. Other operating systems can also support
USB mass storage devices.
During system boot, the ROM BIOS will provide the USB support until the operating system loads.
Since MS-DOS uses the BIOS to communicate with storage devices, utility diskettes that boot DOS
will also function with virtual media.
NOTE: Red Hat Enterprise Linux 3 does not allow you to provide a driver diskette using virtual
media.
Mounting USB Virtual Floppy/USBKey in NetWare 6.5
1. Access iLO 2 through a browser.
2. Select Virtual Media in the Virtual Devices tab.
3. Insert the media into the local floppy drive, select a diskette drive, and click Connect.
Alternatively, select a diskette image to be used and click Connect.
In NetWare 6.5, use the lfvmount command on the server console to assign the device a drive
letter.
The NetWare 6.5 operating system will pick the first available drive letter for the Virtual Floppy
drive. The volumes command can now be used by the server console to show the mount status
of this new drive.
Virtual media 107










