HP Integrated Lights-Out 2 Management Processor Scripting and Command Line Resource Guide

oemhp_CautionValue=0
oemhp_CriticalValue=0
Other sensor targets show system temperatures. The command show system1/sensor3 displays
one of the temperature zone properties. For example:
/system1/sensor3
Targets
Properties
DeviceID=Temp 1
ElementName=I/O Board Zone
OperationalStatus=Ok
RateUnits=Celsius
CurrentReading=32
SensorType=Temperature
HealthState=Ok
oemhp_CautionValue=68
oemhp_CriticalValue=73
SNMP settings
SNMP settings commands enable you to view and modify SNMP settings. SNMP settings are
available at
/map1/snmp1
.
Targets
None
Properties
DescriptionAccessProperty
Sets the first SNMP trap destination address.Read/Write
accessinfo1
Sets the second SNMP trap destination address.Read/Write
accessinfo2
Sets the third SNMP trap destination address.Read/Write
accessinfo3
Enables or disables iLO 2 SNMP alerts. Boolean values accepted.Read/Write
oemhp_iloalert
Enables or disables host agent SNMP alerts. Boolean values
accepted.
Read/Write
oemhp_agentalert
Enables or disables iLO 2 SNMP pass-through. Boolean values
accepted.
Read/Write
oemhp_snmppassthru
Sets the Insight Manager Agent URL.Read/Write
oemhp_imagenturl
Determines if the LOM device responds to anonymous XML queries.
Valid selections can be enabled and disabled.
Read/Write
oemhp_imdatalevel
Examples
You can specify one or more properties on the command line. If there are multiple properties on
the same command line, they must be separated by a space. For example:
set /map1/snmp1 accessinfo1=192.168.0.50 oemhp_imdatalevel=Enabled
24 Command line