HP Insight Remote Support and Insight Online Setup Guide for HP ProLiant Gen8 Servers and HP BladeSystem c-Class Enclosures

A Using AMS
With iLO 3 and earlier, SNMP management used the HP Insight Management Agents running on
the server operating system. With iLO 4, you can use either Agentless Management or the Insight
Management Agents. The default configuration is to use Agentless Management.
iLO 4 Agentless Management uses out-of-band communication for increased security and stability.
With Agentless Management, health monitoring and alerting is built into the system and begins
working the moment a power cord is connected to the server. This feature runs on the iLO hardware,
independent of the operating system and processor. Additional operating system data is collected
when AMS is installed.
Table 4 (page 54) provides a comparison of the information provided by the different HP ProLiant
Gen8 server configurations.
Table 4 Information provided by Agentless Management and Insight Management Agents
Insight Management Agents
1
Agentless Management with
AMS
1
Agentless Management without
AMS
Component
Server health
Fans Fans Fans
Temperatures TemperaturesTemperatures
Power suppliesPower supplies Power supplies
MemoryMemoryMemory
CPU CPUCPU
Storage
Smart Array Smart Array Smart Array
SMART Drive Monitoring SMART Drive MonitoringSMART Drive Monitoring
Internal hard drives attached
to Smart Array
Internal hard drives attached
to Smart Array
Internal hard drives attached to
Smart Array
HBAHBA
Fibre Channel and iSCSI
Tape
External storage
MAC addresses for embedded
NICs
NIC
Standup and embedded Standup and embedded
MAC and IP address MAC and IP address
Link up/Link down trapsLink up/Link down traps
Teaming information
VLAN information
Other
iLO data iLO data iLO data
Firmware inventory Operating system information
(host MIB)
Firmware inventory
Operating system information
(host MIB)
Performance data
Driver/service inventory Configurable thresholds
Logging events to operating
system logs
Clustering information
Pre-Failure Warranty
Alerts
Memory Memory Memory
Drives (physical and logical) Drives (physical and logical)Drives (physical and logical)
CPU
54 Using AMS