HP Insight Remote Support 7.0.9 Monitored Devices Configuration Guide

2. To list registered CIM providers and their current status to make sure that they are all enabled, run the
following command:
# cimprovider –l s
3. Run the following command to check OnlineDiag is installed and make sure it is version B.11.11.16xx
or later.
# swlist | grep –i OnlineDiag
The output should look similar to the following:
4. Run the following command to check that OnlineDiag is reporting that Event Monitoring is Currently
Enabled and that EMS version is A.04.20 or later and the STM is A.49.10 or later:
# /etc/opt/resmon/lbin/monconfig
The output should look similar to the following:
5. Select 'Q' to exit the EMS Monitoring Request Manager Main Menu.
6. Disable EMS hardware monitors for HP-UX 11i v2 and 11i v3.
HP Insight Remote Support 7.0.9:Monitored Devices Configuration Guide Page 97 of 267
Chapter 11: Configuring Integrity HP-UX Servers