HP Insight Remote Support 7.0.9 Monitored Devices Configuration Guide
a.
Scroll down in the SNMP Configuration File to the view systemview included entries.
b.
Comment out the default entries with a # character.
c.
Add the following entry: view systemview included .1 80
d. Click Change.
Verify Communication Between Monitored Device and
Insight RS
To verify communication between your monitored device and Insight RS, complete the following steps:
Verify Connectivity by Sending an SNMP Test Trap to the
Hosting Device
To verify connectivity from the monitored device to the Hosting Device, send an SNMP test trap to the
Hosting Device and then verify the test trap was received in the Insight RS Console.
Use one of the following methods to send an SNMP test trap to the Hosting Device.
l In SMH:
a. Click Settings.
b. In the SNMP Webagent pane, click SNMP Configuration.
c. Scroll to the bottom of the SNMP Configuration screen and in the Test Trap section, click Send
Trap.
l On the command line, type the following command to send a test trap to the Hosting Device:
HP Insight Remote Support 7.0.9:Monitored Devices Configuration Guide Page 73 of 267
Chapter 7: Configuring ProLiant Citrix Xen Servers