HP Insight Remote Support 7.0.9 Monitored Devices Configuration Guide
Discovery Monitoring Basic
Collections
SAN
Collections
Notes
HP MSA 2040 SNMPv1 SNMPv1 Both SNMPv1 and WBEM must be installed and configured.
See "Configuring P2000 G3 Modular Smart Arrays" on page
179.
WBEM WBEM WBEM WBEM
HP P2000 G3
MSA
SNMPv1 SNMPv1 Both SNMPv1 and WBEM must be installed and configured.
See "Configuring P2000 G3 Modular Smart Arrays" on page
179.
WBEM WBEM WBEM WBEM
HP MSA23xx G2 SNMPv1 SNMPv1 Install the WBEM SMI-S Proxy Provider on the host server
and not the MSA itself.
See "Configuring MSA23xx G2 Modular Smart Arrays" on
page 184.
WBEM WBEM WBEM
HP MSA2xxx G1 SNMPv1 SNMPv1 SNMPv1 Configuration collections are not supported, except when the
MSA2xxx G1 is part of a SAN collection.
See "Configuring MSA2xxx G1 Modular Smart Arrays" on
page 189.
HP MSA15xx SNMPv1 SNMPv1 SNMPv1 SNMPv1 See "Configuring MSA15xx Modular Smart Arrays" on page
194.
StoreEasy
Commercial NAS
WMI WMI WMI WMI See "Configuring StoreEasy Storage Systems" on page 197.
HP StoreAll
Network Storage
Systems (formerly
HP IBRIX
Storage)
SNMPv1 SNMPv1 SNMPv1 See "Configuring StoreAll Network Storage Systems" on
page 201.
Table 1.1 Required Monitored Device Communication Protocols and Components for Insight RS Services, continued
HP Insight Remote Support 7.0.9:Monitored Devices Configuration Guide Page 30 of 267
Chapter 1: Understanding Monitored Devices Prerequisites