HP Insight Remote Support 7.0.9 Monitored Devices Configuration Guide
6. Click Apply to commit your changes.
7. Exit the utility and discover your P2000 G3 in the Insight RS Console.
About WBEM on the P2000 G3
The SMI-S provider for the P2000 G3 MSA is integrated in the firmware and delivered with the P2000 G3
series disk arrays. It provides a WBEM-based management framework. Insight RS can interact with this
embedded provider directly and does not need an intermediate proxy provider.
No configuration of WBEMīon the P2000 G3 is necessary.
Add Protocol Credentials and Start Discovery
To discover your monitored devices, complete the following steps:
Create an SNMP Protocol Credential in Insight RS
If your device's SNMP community string is set to public and your community access mode is read
only, Insight RS automatically associates an SNMPv1 protocol with your device. If you use a different
community string or use a nonstandard port, you must create an SNMPv1 protocol credential in the Insight
RS Console.
Important: MSAs with SNMPv3 enabled require SNMPv3 credentials be configured in the
Insight RS Console. Failure to supply SNMPv3 credentials in the Insight RS Console results in
Insight RS displaying only one of the controllers of those MSAs.
To configure SNMPv1 in the Insight RS Console, complete the following steps:
HP Insight Remote Support 7.0.9:īMonitored Devices Configuration Guide Page 181 of 267
Chapter 20: Configuring P2000 G3 Modular Smart Arrays