HP Insight Remote Support 7.0.9 Monitored Devices Configuration Guide
64 bytes from 127.0.0.1: icmp_seq=1 ttl=64 time=0 ms
64 bytes from 127.0.0.1: icmp_seq=1 ttl=64 time=0 ms
After verifying that LOCALHOST responds to the ping command, you can use Ctrl-C or Ctrl-Y to stop
pinging.
l System firmware: The prerequisite system firmware supports the logging of events according to the
FRU Table Version 5 Specification, which is required for Insight Remote Support FRU configuration
tree processing.
All DSxx and ES40 systems must have firmware V5.7–4 or higher.
All other products supported by Insight Remote Support shipped with a compatible firmware version.
In general, users should take advantage of the latest improvements by obtaining the most recent
firmware version available for their platforms.
Fulfilling Required Permissions and Access
Grant Permissions Required to Install ELMC
To install or uninstall ELMC, the user needs all of the following OpenVMS privileges:
l ALTPRI
l BUGCHK
l BYPASS
l CMKRNL
l DIAGNOSE
l IMPERSONATE
l NETMBX
l OPER
l SYSLCK
l SYSPRV
l TMPMBX
When uninstalling ELMC, the user who performs the uninstallation must use the same username originally
used to install ELMC.
The set process command sets privileges for all cluster nodes only when the cluster is served by a single
system disk. However, on a cluster with multiple system disks, you might choose to install ELMC on
nodes served by system disks other than the one serving the node from which you are installing. In that
case, set process does not set privileges on those other nodes (the nodes served by the other system
disks), and ELMC does not install correctly on those other nodes.
To correctly install on clusters with multiple system disks, set up the required privileges as defaults (the
privileges you get when logging on) on all nodes where you wish to install ELMC, instead of using the set
process command.
HP Insight Remote Support 7.0.9:Monitored Devices Configuration Guide Page 114 of 267
Chapter 13: Configuring OpenVMS Servers