7.0.8 Insight Remote Support Release Notes
HP Insight Remote Support 7.0.8 Release Notes
52
Table 20. Required Communication Protocols and Components for HP Insight Remote Support Services (continued)
Required protocols and
components
Discovery
Monitoring
Basic Collections
SAN Collections
Notes
HP Servers
Citrix Xen Server
on ProLiant
Simple Network Management
Protocol (SNMPv1, SNMPv2 or
SNMPv3)
See the “Configuring ProLiant Citrix Xen Servers” chapter in the Monitored
Devices Configuration Guide.
Customer can choose to use either Telnet or SSH to gather SAN Collections
for a ProLiant Citrix Xen server.
Telnet
Secure Shell (SSH)
Hyper-V on
ProLiant
(See Note)
Configuration collections are not supported.
Hyper-V is a role on a Windows server, so you should follow the
configuration instructions for a ProLiant Windows.
See the “Configuring ProLiant Windows Servers” chapter in the Monitored
Devices Configuration Guide.
Windows 2003 on
Integrity
Windows Management
Instrumentation (WMI)
Must install the Integrity Support Pack and all providers that ship with it.
This includes the installation of SNMPv1 and WMI.
See the “Configuring Integrity Windows 2003 Servers” chapter in the
Monitored Devices Configuration Guide.
Simple Network Management
Protocol Version 1 (SNMPv1)
Event Log Monitoring Collector
(ELMC)
Windows 2008 on
Integrity
Windows Management
Instrumentation (WMI)
Must install the HP Integrity Support Pack and all providers that ship with it.
See the “Configuring Integrity Windows 2008 Servers” chapter in the
Monitored Devices Configuration Guide.
Linux on Integrity
Web-Based Enterprise
Management (WBEM)
Configuration collections are not supported, except when the server is part
of a SAN collection. Customer can choose to use either Telnet or SSH to
gather SAN collections for an Integrity Linux server.
See the “Configuring Integrity Linux Servers” chapter in the Monitored
Devices Configuration Guide.
Telnet
Secure Shell (SSH)
HP-UX on
Integrity
Web-Based Enterprise
Management (WBEM)
Install the proper WBEM providers on HP-UX. These generally are part of
the feature set of HP-UX and will update through patches and software
updates on the device as appropriate.
Customer can choose to use either Telnet or SSH to gather SAN collections
for an Integrity HP-UX server.
See the “Configuring Integrity HP-UX Servers” chapter in the Monitored
Devices Configuration Guide.
Telnet
Secure Shell (SSH)
HP Integrity
Superdome 2
Onboard
Administrator
(OA)
Web Services Management
Protocol (WSMAN)
Discovery uses WSMAN and collections use HTTPS. The OA is monitored
using WSMAN, but the Superdome 2 partitions are monitored using WBEM.
See the “Configuring Integrity Superdome 2 Servers” chapter in the
Monitored Devices Configuration Guide.
HTTPS
OpenVMS on
Integrity
Web-Based Enterprise
Management (WBEM)
Must install the OpenVMS WBEM provider.
Configuration collections and discovery only works when the WBEM
providers are installed and the credentials are properly configured.
See the “Configuring OpenVMS Servers” chapter in the Monitored Devices
Configuration Guide.
Event Log Monitoring Collector
(ELMC)