7.0.8 Insight Remote Support Release Notes

HP Insight Remote Support 7.0.8 Release Notes
25
Table 8. Required software components for HP-UX 11i v2 (continued)
Version required
Notes
Operating System
Patch
Requirements
BUNDLE11i patch bundle B.11.23.0409.3
(September, 2004)
In addition, the following patches are required:
PHKL_36288 11.23 Cumulative diag2 driver
and vPars enablement (use in place of
PHKL_32653), requires a reboot after
installation
PHKL_34795 11.23 Cumulative IPMI driver
patch (reboot required after install)
PHSS_37552 1.0 Aries cumulative patch
PHSS_37947 1.0 linker +fdp cumulative patch
PHSS_35055 aC++ Runtime (IA: A.06.10, PA:
A.03.71)
PHSS_36345 11.23 Integrity Unwind Library
These six additional patches for HP-UX 11i v2
are not part of the Bundle11i and must be
installed in addition to it.
How to install patches for HP-UX 11iv2:
Go to www.hp.com/go/hpsc and sign in using
your HP Passport account.
In the left menu, click the Patch management
link. Enter the patch name into the Patch
Management search box and click GO.
OpenSSL Secure
Network
Communications
Protocol
A.00.09.07i.012 (December, 2007) or later
Online Diagnostics
B.11.23.10.05 HPUX 11.23 Support Tools Bundle
(December, 2007) or later
WBEMSvcs (WBEM
Services Core
Product)
A.02.05.08 WBEM Services CORE Product
(December, 2007) or later
You are advised to check the WBEM Services
Release Notes including the WBEM Provider
Compatibility Table for that product version, if
you need to install or update this service.
System
Management Web
(recommended for
event monitoring,
required for
configuration
collection)
A.2.2.7 HP-UX Web Based System Management
User Interface (December 2007) or later
System Management Web is optional, but it
allows you to take full advantage of SFM's
EVWEB GUI component which allows viewing of
events handled by SFM on the host.
If only SysMgmtHomepage version 2.2.6.2 is
present on the server, then the following patch
must also be applied:
For HP-UX 11i v2 (11.23) OE apply patch
PHSS_36870
System Fault
Management
(SFM)
B.07.01.01.yy System Fault Management (May,
2009) or later
See the System Fault Management Release
Notes for more details and additional SFM
prerequisites at www.hp.com/go/hpux-
diagnostics-sfm-docs.
Table 9. Required software components for HP-UX 11i v3
Version required
Notes
HP-UX Operating
Environment
11iv3
EVM-EventMgr B.11.31 or later
Baseboard Management Controller (BMC) firmware
version 05.21 or later
SysMgmtBase B.00.02.03 or later
The Baseboard Management Controller
firmware is only required for rx3600 and
rx6600 servers to provide the correct
Power & Cooling information to System
Fault Manager.