7.0.8 Insight Remote Support Monitored Devices Configuration Guide

Monitored Devices Configuration Guide
Chapter 11: Configuring Integrity HP-UX Servers
complete the following steps:
1. Run the following command to verify the HP WBEM Services for HP-UX component is installed:
# swlist | grep –i WBEM
The output should look similar to the following:
2. To list registered CIM providers and their current status to make sure that they are all enabled, run the
following command:
# cimprovider –l s
3. Run the following command to check OnlineDiag is installed and make sure it is version B.11.11.16xx
or later.
# swlist | grep –i OnlineDiag
The output should look similar to the following:
4. Run the following command to check that OnlineDiag is reporting that Event Monitoring is Currently
Enabled and that EMS version is A.04.20 or later and the STM is A.49.10 or later:
# /etc/opt/resmon/lbin/monconfig
The output should look similar to the following:
HP Insight Remote Support (7.0.8)Page 85 of 248