7.0.8 Insight Remote Support Monitored Devices Configuration Guide

Chapter 8
Configuring Integrity Windows 2003 Servers
This information applies only to Windows 2003 Integrity monitored devices. Event Log Monitoring
Collector (ELMC) is responsible for remote support monitoring on Windows 2003 Integrity monitored
devices. SNMP is necessary for Discovery, and WBEM is necessary for configuration collections.
Fulfill Configuration Requirements
Complete the following steps to configure your Integrity Windows 2003 servers to be monitored by Insight
RS.
Task Complete?
Make sure Insight RS supports your Integrity Windows 2003 server by checking the HP
Insight Remote Support Release Notes.
Install ELMC to the Integrity Windows 2003 server.
Verify SNMP is installed on the Integrity Windows 2003 server.
Verify WBEM is installed on the Integrity Windows 2003 server.
Add the ELMC protocol to the Insight RS Console.
Add the SNMP protocol to the Insight RS Console.
Add the WBEM protocol to the Insight RS Console.
Discover the Windows 2003 Integrity server in the Insight RS Console.
Send a test event to verify connectivity between your Windows 2003 Integrity server
and Insight RS.
Table 8.1 Integrity Windows 2003 Server Configuration Steps
Install the ELMC Software Package on the Monitored
Device
The monitored device must meet the following basic requirements before you install ELMC:
l Processor architecture: Itanium on Integrity Servers
l Operating system: On Integrity Servers, all supported versions of Windows 2003
l TCP-IP configured on the monitored server
l Required Permissions and Access: To install, upgrade, or uninstall ELMC, you must be logged on as
the Administrator or as a user with administrator privileges.
ELMC is required on the Integrity Windows 2003 server so that events can be forwarded to Insight RS.
HP Insight Remote Support (7.0.8)Page 66 of 248