7.0.8 Insight Remote Support Monitored Devices Configuration Guide
Chapter 31
Configuring StoreFabric H-Series Switches
Fulfill Configuration Requirements
Complete the following steps to configure your StoreFabric H-Series Switches to be monitored by Insight
RS.
Task Complete?
Make sure Insight RS supports your H-Series switch by checking the HP Insight
Remote Support Release Notes.
Configure SNMPv1 on the H-Series switch.
Add the SNMP protocol to the Insight RS Console.
Discover the H-Series switch in the Insight RS Console.
Verify the status of the H-Series switch in the Insight RS Console.
Table 31.1 StoreFabric H-Series Switch Configuration Steps
Configure SNMP
Log on to the switch with Telnet and issue the following CLI commands to configure the HP SN6000,
8/20q and 2/8q FC switches to send SNMP traps to the Hosting Device.
1. Open the Admin session:
admin start
2. Configure the SNMP trap destinations:
set setup snmp
3.
After configuration, type y to save and active the SNMP setup.
4. Close the Admin session:
admin end
Create an SNMP Protocol Credential in Insight RS
If your device's SNMP community string is set to public and your community access mode is read
only, Insight RS automatically associates an SNMPv1 protocol with your device. If you use a different
community string or use a nonstandard port, you must create an SNMPv1 protocol credential in the Insight
RS Console.
To configure SNMPv1 in the Insight RS Console, complete the following steps:
1. In a web browser, log on to the Insight RS Console.
2. In the main menu, select Discovery and click the Credentials tab.
HP Insight Remote Support (7.0.8)Page 211 of 248