7.0.8 Insight Remote Support Monitored Devices Configuration Guide
Monitored Devices Configuration Guide
Chapter 25: Configuring StoreAll Network Storage Systems
rocommunity public <Manager IP>
trapcommunity public
trapsink <Manager IP> public
syscontact
syslocation
# ---------------------- END --------------------
2. To add more than one SNMP Manager IP, copy the following lines:
rwcommunity public <Manager IP>
rocommunity public <Manager IP>
trapsink <Manager IP> public
3. After updating the snmpd.conf file, restart the snmpd service:
# service snmpd restart
For more information about the /sbin/hpsnmpconfig script, see “SNMP Configuration” in the hp-
snmp-agents(4) man page. For information about HP System Management Homepage, go to:
http://h18013.www1.hp.com/products/servers/management/agents/index.html.
Important: The /opt/hp/hp-snmp-agents/cma.conf file controls certain actions of the
SNMP agents. You can add a trapIf entry to the file to configure the IP address used by the
SNMP daemon when sending traps. For example, to send traps using the IP address of the
eth1 interface, add the following:
trapIf eth1
Then restart the HP SNMP agents:
service hp-snmp-agents restart
For more information about the cma.conf file, see Section 3.1 of the Managing ProLiant
servers with Linux HOWTO at:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00223285/c00223285.pdf.
Start or Restart Insight Remote Support Services
On the X9000, start or restart the following services:
l System Management Homepage:
# service hpsmhd restart
l SNMP Agent:
# service snmpd restart
l HP SNMP Agents:
# service hp-snmp-agents start
HP Insight Remote Support (7.0.8)Page 185 of 248