7.0.8 Insight Remote Support Monitored Devices Configuration Guide
Chapter 25
Configuring StoreAll Network Storage Systems
Note: HP StoreAll Storage is the new name for HP IBRIX Storage.
Note the following limitations:
l For X9000 systems, the Insight Remote Support implementation is limited to hardware events.
l Some manual configurations require that the X9320 and X9300 nodes be recognized as a X9000
solution. See section "Configure Warranty and Contract Information" on page 186.
Fulfill Configuration Requirements
Complete the following steps to configure your Network Storage Systems to be monitored by Insight RS.
Task Complete?
Make sure Insight RS supports your Network Storage Server by checking the HP
Insight Remote Support Release Notes.
Configure SNMP on the file server nodes.
Restart Insight Remote Support Services.
Add the SNMP protocol to the Insight RS Console.
Discover the Network Storage Server in the Insight RS Console.
Configure warranty and contract information in the Insight RS Console.
Send a test event to verify connectivity between your Network Storage Server and
Insight RS.
Table 25.1 Network Storage System Configuration Steps
Configure SNMP on the File Serving Nodes
1.
Run the /sbin/hpsnmpconfig script, which configures SNMP to integrate the Hosting Device
running on the Windows server with the HP System Management Homepage on the file serving node.
The script edits the /etc/snmp/snmpd.conf file, adding entries similar to the following:
# Following entries were added by HP Insight Management Agents at
# <date> <time> UTC <year>
dlmod cmaX /usr/lib64/libcmaX64.so
rwcommunity public 127.0.0.1
rocommunity public 127.0.0.1
rwcommunity public <Manager IP>
HP Insight Remote Support (7.0.8)Page 184 of 248