7.0.8 Insight Remote Support Monitored Devices Configuration Guide
Chapter 20
Configuring MSA15xx Modular Smart Arrays
Fulfill Configuration Requirements
To configure your MSA15xx Modular Smart Arrays to be monitored by Insight RS, complete the following
steps:
Task Complete?
Make sure Insight RS supports your Modular Smart Array by checking the HP Insight
Remote Support Release Notes.
Configure SNMP on the MSA.
Add the SNMP protocol to the Insight RS Console.
Discover the Modular Smart Array server in the Insight RS Console.
Table 20.1 P2000 and Modular Smart Array Configuration Steps
Configure SNMP on Your MSA15xx Modular Smart
Arrays
Each MSA monitored device has factory-installed SNMP on the device.
To access the Storage Management Utility for the MSA 1510i and configure SNMP for Insight Remote
Support, complete the following steps:
1. Log on to the HP MSA Storage Management Utility.
Note: For basic information about setting up this tool and managing your credentials,
consult the MSAStorage Management Utility documentation at:
http://www.hp.com/support/manuals.
2. Once you have logged on to the utility, select the Configure tab.
3. On the Configure tab, expand the Management Port list for the MSA 1510i.
4. Select the SNMP Service link from the list.
HP Insight Remote Support (7.0.8)Page 164 of 248