7.0.8 Insight Remote Support Monitored Devices Configuration Guide
Monitored Devices Configuration Guide
Chapter 17: Configuring BladeSystem c-Class Enclosures
If using firmware version 3.60 or above, HP recommends registering your c-Class Enclosure through the
OA. For more information, see "Configuring BladeSystem c-Class Enclosures Through the OA" on page
126.
Fulfill Configuration Requirements
Complete the following steps to configure your BladeSystem c-Class Enclosures using SNMP to be
monitored by Insight RS.
Task Complete?
Make sure Insight RS supports your BladeSystem c-Class enclosure by checking the
HP Insight Remote Support Release Notes.
Configure SNMP on the BladeSystem c-Class enclosure.
Add the SNMP protocol to the Insight RS Console.
Discover the BladeSystem c-Class enclosure in the Insight RS Console.
Send a test event to verify connectivity between your BladeSystem c-Class enclosure
and Insight RS.
Table 17.2 BladeSystem c-Class Enclosure Using SNMP Configuration Steps
Configure SNMP on the BladeSystem c-Class Enclosure
If using an OA firmware version below 3.55, you need to configure SNMP in the Onboard Administrator
(OA) before the enclosure can be monitored by Insight RS.
Configuring the enclosure for Remote Support does not allow Insight RS to monitor the blades installed in
the enclosure. You need to configure each blade separately.
Important: If using a primary and standby OA, limit discovery to one of the OAs and not both.
To configure SNMP, complete the following steps:
1. In a web browser, open the HP BladeSystem Onboard Administrator.
2. In the log on screen, type your user name and password and click Sign In.
3. Expand Enclosure Information → Enclosure Settings.
4. Click SNMP Settings.
HP Insight Remote Support (7.0.8)Page 130 of 248