7.0.8 Insight Remote Support Monitored Devices Configuration Guide

Monitored Devices Configuration Guide
Chapter 17: Configuring BladeSystem c-Class Enclosures
Device for both SNMP and service event submissions. The OA cannot be set up to send SNMP
traps to one Hosting Device and service events to another Hosting Device. This is an
unsupported configuration.
Fulfill Configuration Requirements
Complete the following steps to configure your BladeSystem c-Class Enclosures through the OA to be
monitored by Insight RS.
Task Complete?
Make sure Insight RS supports your BladeSystem c-Class enclosure by checking the
HP Insight Remote Support Release Notes.
Register for Remote Support through the Onboard Administrator.
Verify the status of the BladeSystem c-Class enclosure in the Insight RS Console.
Send a test event to verify connectivity between your BladeSystem c-Class enclosure
and Insight RS.
Table 17.1 BladeSystem c-Class Enclosure Through the OA Configuration Steps
Register Remote Support Through the Onboard
Administrator
If using OA firmware version 3.60 or above, you can enable Insight Remote Support for a BladeSystem c-
Class Enclosure using the Onboard Administrator (OA). The OA is not responsible for reporting
information about the blades installed in the BladeSystem c-Class Enclosure. The OA only reports
enclosure issues, such as problems with fans, power supplies, and media bays.
Important: If using a primary and standby OA, ensure that the firmware version for both OAs is
3.60 or higher.
Registering the enclosure does not register the individual blades installed in the enclosure. You need to
configure each blade separately.
To register for Remote Support through he OA, complete the following steps:
1.
In a web browser, log on to the HP BladeSystem Onboard Administrator (https://<OA hostname or
IP address>).
2. Navigate to Enclosure Information Enclosure Settings Network Access, and click the
Protocols tab.
3. Make sure the Enable XML Reply check box is selected. If this check box is not selected, the
OAcannot be enabled in Insight RS.
4. Navigate to Enclosure Information Enclosure Settings Remote Support, and click the
Registration tab.
HP Insight Remote Support (7.0.8)Page 127 of 248